Quick answer: If you own a Fisher & Paykel DE or DC condenser, DH heat pump, or Haier HDHP, HDC, HDV or HDY dryer, the parts that fail most are the heater element (condenser runs cold), the condensate or drain pump (water on the floor), the belt-and-bearing service kit (squeal, drum stops) and, on DH9060 and HDHP90 heat pumps, the drum motor. Stocked in Australia and dispatched from Sydney the day you order (12pm Sydney cut-off). Match the model number on the sticker, not the badge.
Last updated September 2026
The fault, the usual part and the live product
You typed the model number into a search bar and got nothing, or a listing for a dryer wearing a different badge. That is the Fisher & Paykel and Haier problem in one sentence: shared platforms, so your part is often listed under the other name. Start with the symptom.
| What you’re seeing | What it usually is | The part |
|---|---|---|
DE8060P1, DE8060P2 or DC8060 runs the full cycle, clothes come out cool and damp | Heater element open circuit, or its thermal cut-out tripped | Fisher Paykel Condenser Dryer Heater, DE8060P1, DE8060P2 |
Puddle under a condenser dryer, or tank-full warning with an empty tank | Condensate pump stuck, split, or float jammed with lint | Fisher & Paykel Condensate Pump, DE8060P1, DE8060P2, DE8060P3 |
DH8060 or DH9060 heat pump (Haier HDHP80) stops with a drain or tank warning | Drain pump failed or blocked | FISHER & PAYKEL HAIER Dryer drain Pump DH8060P1 DH8060P3 DH9060C1 DH9060P1 HDHP80A1 HDHP80E1 |
Squeal or rumble that rises with the load, drum still turning | Rear bearing, felt guides and tension wheel worn | Fisher & Paykel Condenser Dryer Service Kit DE8060P1 DE8060P2 |
Motor runs, drum does not turn, belt lying in the drum | Drive belt snapped or off the pulley | Fisher Paykel Dryer Drive Belt DH9060C1, DH9060P1, DE8060P1, DE8060P2 |
DH9060FS1 or DH9060FSG1 screeches at start, or hums and will not turn, drum free by hand | Drum motor bearings. Confirm first; it is the expensive one | Fisher & Paykel Heat Pump Dryer Motor DH9060FS1 DH9060FSG1 |
Long cycles, weak airflow, rattle or scrape behind the drum | Fan cracked or shaft worn | Fisher & Paykel Dryer Fan + Shaft DE45F56EW1 DH8060C1 DH9060C1 DH9060P2 DH9060PG |
Fisher & Paykel or Haier? Same dryer, different badge
Fisher & Paykel sits inside the Haier group; the dryers come off shared platforms. The DE8060P1, DE8060P2 and DE8060P3 condensers and the DC8060 are the Haier HD80-01 and HDC80E1 behind a different front. The DH8060 and DH9060 heat pumps (P1, P2, P3, C1, PG, FS1, FSG1) are the Haier HDHP80 and HDHP90 family: HDHP80A1, HDHP80E1, HDHP80AN1, HDHP90AN1 and HDHP90ANB1. The vented HDV and HDY Haier dryers sit alongside Fisher & Paykel’s DE45F56EW1.
So when your Fisher & Paykel model turns up nothing, look for the Haier sibling. The Fisher & Paykel model pages map the families; the wider range is in the dryer parts store and under Fisher & Paykel parts. The badge on the front is marketing. The sticker inside the door is engineering.
Condenser dryers: DE8060, DC8060, HD80-01 and HDC80E1
The DE8060P2 has run its ninety minutes and the towels are still wet, warm only from the tumbling. Nine times in ten that is the heater. It sits in a duct behind the drum with a thermal cut-out bolted to it; when the element goes open circuit the drum turns, the fan runs, nothing warms. Dryer unplugged, meter across the element, then the cut-out. The condenser dryer heater fitment guide walks through it; the Haier-badged listing is the Fisher Paykel Haier Condenser Dryer Heater.
Water on the floor is the other big one. The pump that lifts condensate up to the tank in the door lives in a sump that fills with lint. When it sticks, the tank-full warning comes on over an empty tank, or the sump overflows. On the Haier badge it is the Haier Condensate Pump HD80-01, HDC80E1, HDHP80AN1, HDHP90AN1, HDHP90ANB1. If the pump runs but the sump keeps flooding, clean the float and hoses first.
Squeal under load on the DE8060 is the rear bearing and felt guides. The service kit in the table does belt, bearing, guides and tension wheel in one teardown; the DE8060P1 and DE8060P2 model guide shows the order the panels come off. The HD80-01 and HDC80E1 take the Haier Dryer Drive Belt HD80-01, HDC80E1.
Heat pump dryers: DH8060, DH9060, HDHP80 and HDHP90
A DH9060FSG1 that screams for ten seconds at the start of every cycle, or hums and gives up, is telling you the drum motor bearings are going. The motor is the serious part on this platform, $350–450 as a band, so check before it goes in the cart. Unplug, open the door, turn the drum by hand. It should roll with light, even belt drag.
- Drum free by hand, motor hums or screeches and will not run: the motor.
- Drum stiff, grinding or catching: rear bearing or rollers. A motor will not fix it.
- Belt loose in the drum: the belt.
- Runs quietly, never warms: the refrigerant circuit. Compressor and sealed system are licensed-repairer work only. Do not open it.
The Haier-badged motor is the Haier Heat Pump Dryer Motor HDHP90AN1 HDHP90ANB1. Drain warnings are the drain pump in the table; the drain pump replacement guide covers the teardown. Showing a code instead of a symptom? Decode it first: Fisher & Paykel dryer error codes, Haier dryer error codes, and the heat pump and condenser dryer error codes guide.
Lint in a ring around the door is the Fisher Paykel and Haier Dryer Door Seal Gasket, shared across both families. A door that drops or has to be lifted shut is the Fisher & Paykel Dryer Door Hinge Plate; the hinge plate guide is a ten-minute read for a ten-minute job.
Vented dryers: HDV, HDY and DE45
Haier’s HDV40A through HDV70E and the HDY60M are the wall-hung vented dryers in rental laundries across the country, and the part they most often need is the Haier Dryer Wall Mounting Bracket Kit HDV40A, HDV50E, HDV60A, HDV70E, HDY60M, because brackets get left behind at the last house. The Fisher & Paykel, Haier and Whirlpool bracket guide shows the hole pattern; the every-brand bracket table covers the rest. HDY-M40 owners have their own HDY-M40 faults and fixes guide.
Two vented faults to know. Hums and will not start, but spins up if you flick the drum: the motor run capacitor. Runs only with the door pushed hard shut: the door switch. We do not hold every capacitor and door switch, so send the model number for an honest yes or no. Belts for the DE45F56EW1 are in the drive belt guide.
Where the model sticker is and how to match it
Open the door. On the condenser and heat pump dryers the sticker is on the frame around the door opening; on the vented HDV and HDY it is inside the door rim or on the back panel near the vent. Copy the whole thing, because the suffix bites: DH9060P1 and DH9060P2 are different builds, DH9060FS1 and DH9060FSG1 a different generation again, and HDHP80A1, HDHP80E1 and HDHP80AN1 are separate listings. Search the full model number on the site; the find your model page shows where it hides on every brand. Not sure which listing is yours? Send the model number through the contact page and we check before you order.
DIY or repairer?
Belts and hinge plates are $20–40 parts and a screwdriver job. Pumps and the condenser heater sit in the $70–130 band and want a panel off, a photo of the wiring first, and a meter reading that confirms the fault. A repairer’s call-out and diagnosis runs $100–165 before parts, so a confirmed motor fitted yourself beats replacing a heat pump dryer. The same motor fitted on a guess does not.
Stop and call a licensed person when the fault is heating on a heat pump dryer (sealed refrigerant circuit); when the dryer is hard-wired rather than plugged in (isolate at the switchboard and the wall, and in most Australian states that work must be done by a licensed person); or when symptoms point to the control board, fitted after diagnosis, never on a guess. Never bypass the door switch.
Frequently asked questions
Q: Do Fisher & Paykel and Haier dryers use the same parts?
A: Often, yes. The DE8060 condensers and the HD80-01 and HDC80E1, and the DH8060 and DH9060 heat pumps and the HDHP80 and HDHP90, are shared platforms. A listing under the other badge is normal. Match the model number on the sticker.
Q: My condenser dryer turns but does not heat. Is it the heater?
A: On the DE8060 and HD80-01 family it usually is, or the thermal cut-out bolted to it. Meter both with the dryer unplugged before buying. If both test fine, the thermostat or board is next: diagnosis, not a parts order.
Q: How do I know the heat pump motor is the fault?
A: Unplug, open the door, turn the drum by hand. Free drum plus a motor that hums, screeches or will not run: the motor. Stiff or grinding drum: bearing or rollers. Quiet dryer, no heat: the refrigerant circuit, licensed only.
Q: Can I regas a heat pump dryer or replace its compressor myself?
A: No. The sealed refrigerant circuit on a heat pump dryer is licensed-repairer work in Australia. We do not sell sealed-system parts.
Q: Why does my dryer say the tank is full when it is empty?
A: The condensate pump or its float is jammed with lint or has failed. Clean the sump and float first; if it keeps happening, replace the pump listed for your model.
Read the sticker, search the model number on the site. If the listing wears the other badge, that is the shared platform. Not sure? Send the model number through the contact page and we match it before you order. Dispatched from Sydney’s Northern Beaches the day you order when it is in by 12pm Sydney time.
Disclaimer: this article is general information only and is provided without warranty of any kind. Appliance designs vary between models and production runs — always follow the manufacturer’s instructions, switch off and unplug the appliance before starting any work, and confirm parts against the model number on your appliance’s model sticker. Any repair is undertaken at your own risk and Oz Appliance Spares accepts no liability for injury, loss or damage arising from work performed after reading this guide, to the maximum extent permitted by law. If in doubt, use a qualified technician.
Appliance Spares

DE8060P1, DE8060P2 or DC8060 runs the full cycle, clothes come out cool and damp
Puddle under a condenser dryer, or tank-full warning with an empty tank
DH8060 or DH9060 heat pump (Haier HDHP80) stops with a drain or tank warning
Squeal or rumble that rises with the load, drum still turning
DH9060FS1 or DH9060FSG1 screeches at start, or hums and will not turn, drum free by hand
Long cycles, weak airflow, rattle or scrape behind the drum